Eaton XV-440 Series Pressure Valve Commissioning

Model:‌ XV-440-12TSB-1-10 (12 GPM, 10Vdc Input, T-Slot Body)
System Compatibility:‌ Hydraulic circuits ≤210 bar (3000 PSI)


Pre-Debugging Requirements

  1. Safety Lockout

    • Depressurize system: Engage hydraulic lockout/tagout (LOTO# HV-03)
    • Verify accumulator bleed-down (pressure gauge ≤1 bar)
  2. Setup Verification

    plaintextCopy Code
    • Fluid: ISO VG 46 hydraulic oil (Δvisc ≤20% from baseline)
    • Filtration: Beta₅≥200 (NAS Class 7)
    • Ambient Temp: 5-50°C (derate 0.7%/°C beyond range)
    • Mounting torque: 35 Nm ±3 Nm (SAE J1926-1 flange)

Debugging Sequence

STEP 1: Electrical Validation

plaintextCopy Code
[Wiring Check]
Terminal 1: +10Vdc ref (Shield: Drain to chassis)
Terminal 2: Command signal (0-10Vdc = 0-210 bar)
Terminal 3: Sensor feedback (4-20mA output)
Terminal 4: 0Vdc

[Test Parameters]
• Insulation resistance: >20MΩ @ 500Vdc (IEC 60204-1)
• Signal noise: <50mVpp with 10Hz low-pass filter

STEP 2: Mechanical Zero Calibration

plaintextCopy Code
1. Disconnect electrical connector
2. Rotate manual override screw CCW until stop (hear 3 clicks)
3. Apply test pressure @ 10 bar → confirm drain port leakage <30 ml/min

STEP 3: Dynamic Response Test

plaintextCopy Code
Command Signal Expected Response Tolerance
────────────── ───────────────────── ──────────
Ramp 0-10V/10s Linear pressure rise Hysteresis ≤2% FS
10V step Settling time ≤450ms Overshoot ≤8%
1Hz sine @ 5V Phase lag ≤15° Gain error ±3dB

Diagnostic Parameters

Feedback Signal System State Corrective Action
4.0mA ±0.1mA Under-range fault Check sensor coupling
22.5mA Over-pressure trip Verify relief valve setting
3.2mA steady Spool sticking Flush with Eaton CLEAN-SEAL kit

Software Configuration (Via Eaton Pro-FX)

iniCopy Code
; XV-440 Configuration File
[PRESSURE_PROFILE]
Ramp_Rate=12 bar/sec ; Max allowable slew rate
Deadband_Comp=0.8% ; Hysteresis compensation
Pressure_Limit=195 bar ; Soft cutout threshold

[DIAGNOSTICS]
Fault_Delay=1.5 sec ; Spike suppression window
Auto_Zero=ENABLED ; Zero-point recalibration


Critical Warnings

 ‌HAZARDOUS CONDITIONS

  • NEVER bypass mechanical stop during calibration → risk of sudden pressure release
  • Maintain fluid velocity ≤6 m/sec in drain line
  • Disable auto-zero if fluid contamination >ISO 17/14
  • FAULT RECOVERY PROTOCOL

    plaintextCopy Code
    1. Power cycle valve
    2. Force manual override CW→CCW ×3
    3. Execute factory reset: Hold test button 10s until LED flashes red


    Performance Validation

    Test 1: Static Pressure Holding

    plaintextCopy Code
    • Setpoint: 150 bar
    • 5-min drift: ≤3 bar (ISO 10767-1 Class C)

    Test 2: Step Load Response

    plaintextCopy Code
    Apply 25% → 75% load step:
    Recovery time: ≤800ms
    Peak deviation: ≤12%

XV-440-12TSB-1-10  EATON    PDF

XV-440-12TSB-1-10  EATON

··········································································································

Our advantages:

1. The brand new product comes with a one-year

comprehensive warranty.

2. All products undergo strict quality inspections.

3. Contact us and our team will provide competitive

quotes and procurement plans.

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “XV-440-12TSB-1-10 EATON  10.4″/12.1″/15″ MICRO PANEL”

Your email address will not be published. Required fields are marked *