GE Grid Solutions S732DVR-EST1 Installation Manual
Model: S732DVR-EST1 (DIN-rail mounted, 32-channel)
Certification: UL 508 / IEC 61850-3 compliant
Pre-Installation Requirements
-
Environmental Conditions
- Operating temperature: -20°C to +60°C (derate 1%/°C >50°C)
- Humidity: 5-95% RH non-condensing
- Altitude: ≤2000m (3000m with pressure compensation)
-
Power Supply
plaintextCopy CodeVoltage Range: 24V DC ±10% or 110-240V AC (auto-sensing)
Power Consumption: 45W max (all channels active)
Grounding: ≤4Ω to facility ground (6AWG copper wire required)
-
Network Preparation
- Port configuration:
textCopy Code
ETH1: 10/100/1000BASE-T (RJ45) - Primary comms
ETH2: 100BASE-FX (SFP) - Redundant ring
- VLAN tagging: IEEE 802.1Q compliant
- Port configuration:
Mechanical Installation
Step 1: DIN Rail Mounting
- Align unit with TS35 rail (EN 60715)
- Engage upper latch, then press downward until lower clip snaps
- Verify secure attachment (pull test ≥50N force)
Step 2: Cable Connections
Port | Specification | Torque |
---|---|---|
Power Input | 2-pin removable terminal (Phoenix) | 0.6 Nm |
Camera Inputs | BNC (75Ω impedance) | Hand-tight |
Alarm I/O | 16-pin removable header | 0.4 Nm |
Configuration Procedure
-
Initial Boot
- Hold
RESET
button for 5s during power-up - Default IP:
192.168.1.100
(DHCP disabled)
- Hold
-
Web Interface Setup
iniCopy Code[System_Config]
Storage_Allocation=JBOD ; RAID0/1/5 optional
Motion_Detection=Area+Time ; Pixel threshold=15%
Retention_Period=30d ; Auto-overwrite enabled
-
Camera Pairing
- Supported protocols: ONVIF Profile S, RTSP, GB/T28181
- Auto-discovery via
Device Manager → Add Camera