Caterpillar Industrial Controller 164-8940
PN: 164-8940 | Compatibility: CAT® Heavy-Duty Equipment Series
1. Pre-Operation Inspection
- Visual Check
Verify:- No physical damage on 24-pin connector
- Intact sealing gasket (IP67 rating)
- Legible part number labeling
- Electrical Verification
Input Voltage: 24V DC ±10% Insulation Resistance: ≥100MΩ @500V DC Current Draw: ≤2.1A @full load
2. Installation Procedure
Step 1: Mechanical Mounting
- Use M6 stainless steel bolts (torque: 8 Nm ±0.5 Nm)
- Maintain ≥50mm clearance from heat sources
Step 2: Wiring Connections
Terminal | Function | Cable Spec |
---|---|---|
X1-1 to 4 | CAN Bus (J1939) | Shielded twisted pair |
X2-7/8 | Emergency Stop Input | 1.5mm² (min) |
X3-12 | Analog Output (4-20mA) | 0.75mm² (max 100m run) |
Critical Note:
- Apply dielectric grease (CAT #238-0613) on all connectors
- Route power cables separately from signal lines
3. Power-Up Sequence
- Apply control power first → wait for STATUS LED solid green
- Enable main power → verify no alarm codes on display
- Perform self-test: Hold MODE button for 5s until diagnostic cycle completes
4. Operational Modes
LED Indicator | State | Action Required |
---|---|---|
Green flashing | Standby mode | Initiate start sequence |
Amber solid | Warning condition | Check error history log |
Red fast blink | Critical fault | Immediate shutdown |
··········································································································