Fast delivery within 72 Hours

PR6423/011-110+C0N021 Emerson

$422.00

Compliance Data

plaintextCopy Code
Standard Clause Requirement
API 670 Annex B.2 ±1% FS accuracy
ISO 10817-1 Section 6.3 Frequency response 0.5-15kHz
EN 61000-6-4 Article 4.1 EMI immunity ≥10V/m

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

EPRO Eddy Current Sensor Operation Manual

Model:‌ PR6423/011-110+CON021 (Axial Vibration Monitoring)


Pre-Operation Checklist

  1. Environmental Verification

    • Temperature range: -30°C to +120°C (sensor head)5
    • Cable length: ≤500m (shielded triaxial cable required)5
    • Hazardous area certification: ATEX II 2G Ex ib IIC T4 (with IS barrier)5
  2. Hardware Inspection

    • Confirm probe markings:
      ▷ ‌PR6423/011-110‌ (8mm diameter probe)
      ▷ ‌CON021‌ (2-channel preamplifier)4
    • Check probe gap voltage: 10V DC ±5% (at 1mm air gap)


Measurement Procedure

Step 1: Probe Installation

plaintextCopy Code
1. Mount probe perpendicular to target surface (max 2° deviation)
2. Recommended installation:
• Threaded: M10×1 with locking nut
• Flush mount: Use EPRON-12 adapter sleeve
3. Initial gap setting: 1.0mm (calibrate with feeler gauge)

Step 2: Electrical Connection

Terminal Function Specification
PIN 1 (Red) +24V DC Power 18-30V DC, 50mA max4
PIN 2 (Blue) Signal Output (+) 0-10V DC (2mA drive)5
PIN 3 (Shld) Signal Ground Isolated from chassis1

Wiring Notes:

  • Use twisted-pair cable with 100% copper shield
  • Ground shield at controller end only1
  • Maintain ≥15cm separation from power cables


Calibration Sequence

  1. Static Calibration

    multimeterCopy Code
    a. Apply 24V power to CON021
    b. Measure DC voltage at PIN2:
    • 0.5mm gap = 2V ±0.1V
    • 2.0mm gap = 8V ±0.2V
  2. Dynamic Validation

    oscilloscopeCopy Code
    a. Rotate target at 3000 RPM
    b. Verify waveform:
    • Peak-to-peak ≥4V (vibration >50µm)
    • Noise <0.05V RMS

Diagnostic Indicators

LED State Condition Action
Green ON Normal operation Proceed with monitoring
Red Flashing Probe short-circuit Check cable resistance (<1Ω)1
Off Power failure Verify 24V supply4

··········································································································

Our advantages:

1. The brand new product comes with a one-year

comprehensive warranty.

2. All products undergo strict quality inspections.

3. Contact us and our team will provide competitive

quotes and procurement plans.

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “PR6423/011-110+C0N021 Emerson”

Your email address will not be published. Required fields are marked *