Fast delivery within 72 Hours

DECS-200N-C1 BASLER ELECTRIC

$222.00

HMI Navigation Path:

textCopy Code
MAIN MENU > SYSTEM CONFIG > COMMUNICATION
• MODBUS RTU: Address 01, Baud 19.2k, Even parity
• IEC 61850: Import SCL file EX2100_V2.cid

ALARM CONFIG:
Priority 1: Field ground (64F) - Auto trip
Priority 2: Thyristor overtemperature - Alarm only

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

DECS-200N-C1 Excitation System Commissioning Procedure


Pre-Energization Checks

 ‌Hazard Prevention:

  1. Isolate generator terminals (rack-out circuit breaker)
  2. Ground field windings with 35mm² cable
  3. Verify dielectric strength (5kV AC for 1min @ bushings)

Validation Steps:

plaintextCopy Code
1. CTR/VTR Settings:
• Field CT: 5000/5A (Verify burden ≤0.1VA)
• PT Ratio: 13.8kV/120V

2. Insulation Resistance:
- Control circuits: >100MΩ @ 500VDC
- Power circuits: >500MΩ @ 2.5kVDC

3. Ground Continuity: <0.1Ω (terminal X5-17 to station grid)


Hardware Configuration

DIP Switch Settings (Front Panel):

SW Group Position Function
SW1 1-ON Auto Voltage Reg
4-ON CANbus enabled
SW2 2-OFF Breaker sync disable

Terminal Wiring:

textCopy Code
X3-1 → Generator PT (Ph-A) [2.5mm² shielded]
X3-11 → Field +ve [35mm², 90°C rated]
X5-9 → Emergency trip input [Dry contact, 24VDC]

Power-Up Sequence

mermaidCopy Code
graph LR
A[Control Power ON] --> B[Initialize HMI]
B --> C{Self-Test Result}
C -->|PASS| D[Enable DC supply]
C -->|FAIL| E[Diagnostic Code 0xE7]
D --> F[Pre-charge resistor bypass]
F --> G[Field breaker close]

Critical Timings:

  • DC link pre-charge: 3.2s ±0.5s
  • HMI boot time: ≤15s

Calibration Procedure

1. Voltage Matching

plaintextCopy Code
a. Set DECS-200N to MANUAL mode

b. Adjust FVR (Field Voltage Reg) until:
Gen Volts = Grid Volts ± 0.25%

c. Engage sync check relay (59G)

2. PID Tuning (Auto Mode)

Parameter Default Optimization Range
Kp 2.5 1.8-3.2
Ti 4.0s 3.5-8.0s
Stab. Gain 0.35 0.2-0.5
textCopy Code
*Note: Use step response test (2% ΔVref) to achieve:
- Rise time <0.5s
- Overshoot ≤5%*

DECS-200N-C1 BASLER ELECTRIC PDF

DECS-200N-C1 BASLER ELECTRIC l

···········································································································

Our advantages:

1. The brand new product comes with a one-year

comprehensive warranty.

2. All products undergo strict quality inspections.

3. Contact us and our team will provide competitive

quotes and procurement plans.

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “DECS-200N-C1 BASLER ELECTRIC”

Your email address will not be published. Required fields are marked *